Flue Systems

- Horizontal and vertical flue systems


Remeha has made the installer's job easier with the launch of a low profile flue terminal and a telescopic flue to support the Avanta range. This completes its comprehensive flue range - which also includes vertical flues, plume management systems and balcony terminal kits.

The new low profile flue terminal has two important advantages over conventional terminals. First, it is more aesthetically pleasing - an important consideration if the boiler is to be installed in a kitchen or elsewhere where it will be exposed. Secondly, it reduces the clearance required above the boiler by around 80mm, from 250mm to 170mm, thus increasing flexibility when positioning the boiler.

The telescopic flue can easily accommodate wall thicknesses of 250mm to 450mm with no cutting involved. It is comprised of a tough polyphenylene sulphide (PPS) plastic inner flue and a white painted steel outer pipe, offering clean lines and durability.

telescopic-flue.jpg       NEWFluei2.jpg


Technical Information

The Avanta Range is designed for room sealed operation and no compartment ventilation is required. The Avanta Range must be installed with the correct Remeha approved flue accessories.


fluesi.jpg

NOTE: The 90° Bend supplied with the horizontal flue kit is not included in any equivalent length calculations.


Boiler Type
12v/15v/18v/24v/30v 18s/24s/30s
24c/28c/35c/39c
Telescopic flue length 'L' (mm)
*See below
250 - 450mm
250 - 450mm

*This can be used with the original bend - please contact Remeha technical department for further information.
NOTE: Telescopic Flue System - 450mm for Standard Flue. 1000mm Flue Option also available. 60/100 Extended Telescopic Flue.


Heating Boilers:

Boiler Type
12v
15v
18v
24v
30v
Flue Diameter (mm)
80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
Max Vertical/Horizontal
Flue Length 'L' (m)

34
8
34
8
34
8
34
8
34
8
 







System Boilers:

Boiler Type18s
24s
30s
Flue Diameter (mm)80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
Max Vertical/Horizontal
Flue Length 'L' (m)
29
6
29
6
29
6








Combi Boilers:

Boiler Type24c
28c
35c
39c
Flue Diameter (mm)80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
80/
125
60/
100
Max Vertical/Horizontal
Flue Length 'L' (m)
 296
29
6
30
7
25
5









90degree.jpg
45degree.jpgFor each 90° bend deduct 1.4m from the maximum flue length.
For each 45° bend deduct 0.65m from the maximum flue length.
  90° Bend 45° Bend
NOTE: For flue lengths in excess of details in above table larger flue systems are available - please contact Broag for further details.

 

Position Type
DescriptionDiameterLength/Angle
AHorizontal Concentric Flue Kit 60/100 mm
600 mm
B
Vertical Concentric Flue Kit
60/100 mm
600 mm
C
Cuttable Concentric Flue Extension60/100 mm
500 mm
D
Non Cuttable Concentric Flue Extension
60/100 mm
500 mm
E
Non Cuttable Concentric Flue Extension
60/100 mm
1000 mm
F
Concentric Flue Bend
60/100 mm
90°
G
Concentric Flue Bend
60/100 mm
45°
H
Wall Bracket
60/100 mm
n/a
I
Pitched roof weather slate for 60/100 mm flue 
100 mm
Flexible
J
Flat roof weather slate for 60/100 mm flue
100 mm
400x600 Sq


 

 